Intermodulation » History » Version 11

GOMEZ, Ramon, 12/13/2015 07:16 PM

1 10 GOMEZ, Ramon
{{toc}}
2 10 GOMEZ, Ramon
3 10 GOMEZ, Ramon
h1. 3.3 Intermodulation (IMD)
4 2 HAENNIG, Gerald
5 4 HAENNIG, Gerald
Intermodulation measures the non-linear distortions on the signal.
6 2 HAENNIG, Gerald
7 2 HAENNIG, Gerald
8 11 GOMEZ, Ramon
h2. 3.3.1 Creation of two tones for Intermodulation test
9 5 HAENNIG, Gerald
10 5 HAENNIG, Gerald
To measure the intermodulation in our system is necessary to generate two sinus at the input of the optical system and to evaluate them at the output. As the signal generator couldn't provide two sinus at the same time it has been decided to use the USRP with a Labview program to do so.  
11 5 HAENNIG, Gerald
12 5 HAENNIG, Gerald
An already programmed Labview example in which one tone was generated was modified in order to do so:
13 5 HAENNIG, Gerald
14 5 HAENNIG, Gerald
p=. !{width:700px}Main_Front_Panel.png!
15 5 HAENNIG, Gerald
Figure 1. Front Panel used to generate two sinus
16 5 HAENNIG, Gerald
17 5 HAENNIG, Gerald
Then, the part of the Labview block in which the tone was generated was duplicated, adding a new output and having the result observed below: 
18 5 HAENNIG, Gerald
19 7 HAENNIG, Gerald
p=. !{width:400px}Generate_Waveform.png!
20 5 HAENNIG, Gerald
Figure 2. Block modified to generate two sinus
21 5 HAENNIG, Gerald
22 5 HAENNIG, Gerald
After the Labview modifications it could be observed at the output of the USRP the two tones:
23 5 HAENNIG, Gerald
24 5 HAENNIG, Gerald
p=. !{width:500px}two_sinus.jpg!
25 5 HAENNIG, Gerald
Figure 3. Two sinus output from the USRP
26 5 HAENNIG, Gerald
27 11 GOMEZ, Ramon
h2. 3.3.2 Measurement results
28 5 HAENNIG, Gerald
29 3 HAENNIG, Gerald
p=. !{width:700px}intermodulation_700MHz.png!
30 9 HAENNIG, Gerald
Figure 4. 3rd order Intermodulation vs Input Power @ 700 MHz
31 1 GOMEZ, Ramon
32 3 HAENNIG, Gerald
p=. !{width:700px}intermodulation_1000MHz.png!
33 9 HAENNIG, Gerald
Figure 4. 3rd order Intermodulation vs Input Power @ 1000 MHz
34 3 HAENNIG, Gerald
35 3 HAENNIG, Gerald
p=. !{width:700px}intermodulation_2000MHz.png!
36 9 HAENNIG, Gerald
Figure 4. 3rd order Intermodulation vs Input Power @ 2000 MHz